Important
After every application, clean the steam nozzle and wand with a non-abrasive, damp cloth
to remove possible liquid residue.
Risk of injury
Avoid skin contact with the steam nozzle and wand while cleaning!
7

CLEANING AND MAINTENANCE

Regular and accurate care is very important for the performance, longevity and safety of your machine.
Caution!
Always switch off the machine (power switch in lower position), disconnect the power cord
and let the machine cool down to room temperature (for at least 30 minutes) before
cleaning.
Never submerse the machine in water; there is a danger of an electric shock.

7.1 General cleaning

Daily cleaning:
The portafilters, filters, water tank, drip tray, drip plate of the drip tray, measuring-spoon and tamper
require daily cleaning. Clean with warm water and/or with a food safe detergent.
Clean the shower screen and the group gasket in the lower part of the group and remove visible dirt
without disassembling the parts.
The portafilters, drip tray and water tank are not dish washer safe.
Cleaning as necessary:
Clean the steam and hot water wands after every use.
Clean the machine when the it has been switched off and cooled down.
Depending on usage, please refresh the boiler water every 2 – 3 weeks by discharging about 0.8L of hot
water from either the hot water wand or brew group.
Use a soft, damp cloth for cleaning.
Never use abrasive or chloric detergents!
Empty the drip tray regularly before it is full to avoid spillage.

7.2 Brew group cleaning

Brew group cleaner is available at your specialized dealer allowing you to clean and degrease the brew
group very easily with the included blind filter. Brew group cleaning should be carried out after approx.
every 90 - 140 cups.
Follow the instructions as noted below:
1
Heat up the machine until the operating pressure has been reached (1.0-1.2 bar).
2
Place the blind filter into the portafilter.
3
Fill the blind filter with group cleaner according to the package instructions.
4
Clamp the portafilter into the brew group.
5
Operate the brew group lever. The blind filter will fill with water.
6
Let the detergent react, moving the group lever into the middle position, approx. 45°. (Do not move it
into the lower position.)
7
Move the lever into the lower position after approx. 20-60 seconds to allow the fats and oils to be
discharged by the infusion cylinder.
8
Repeat steps 5-7 up to 10 times, until only clear water is discharged out of the infusion cylinder.
9
Rinse the portafilter and the blind filter with fresh water. Then replace it.