Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

5.2.2.6 Fuel System

The Geko electric power generator units are serially equipped with fuel tanks which simultaneously serve as
the basic frame of the electric power generator unit.
If it is necessary to have a larger stock of fuel for longer operation period without fuel replenishment it is
possible to install an external fuel tank using special brackets. The tank is connected with the electric power
generator unit with the following pipelines:
Main line of fuel supply to the engine fuel pump.
Return fuel line from the fuel pump and injectors.
An additional cock may be installed in the electric power generator unit for switching between fuel tanks. In
the left position of the switch (Fuel Tank 1) the electric power generator unit is fed from the built-in fuel tank.
Water trap
Hand pump
Fuel cock
In the right position of the switch (Fuel Tank 2) the electric power generator unit is fed from the external fuel
tank.
The data for the determination of the fuel pipe diameters is shown in the corresponding specifications
(assembly drawing).
In any case the minimum cross-section of fuel lines is as follows:
– main feeder line 10 x 1 mm
– return line 10 x 1 mm
These instructions refer to the total length of the fuel system up to 5 m.
Fuel filter
Fuel pump
Built-in fuel
External fuel
tank
tank
Return fuel
line
Feed fuel
line
Fuel cock (optional)
Fuel cock (optional)
26
Fuel filter with water
trap (standard)
Fuel filter with water
trap (optional)