7.7 Changing the stroke measuring system

7.7.1 Main components

LE 100 measuring
system
CAUTION
Due to the adjustment work required, the stroke measuring
system should only be changed by specialist personnel.
Different measuring systems are used in the drives. This operating
manual describes two measuring systems.
• LE 100
• TTK70
For more information on the optical stroke measuring systems,
refer to the separate operating manuals.
The LE 100 measuring system is a non-contact incremental
measuring system. In conjunction with the measuring tape in the
SCHUNK axes, the sensor head supplies a sin/cos signal and a
periodically recurring reference signal.
Measuring system modules
1
Reading head LE 100
3
Marking on magnetic strip 4
5
Covering tape
07.00 | LDH and LDK | Assembly and Operating Manual | en | GAS360923
Maintenance and repair work
2
Magnetic strip LE 100
Distance between reading
head and covering tape
129