7.7 Changing the stroke measuring system
7.7.1 Main components
LE 100 measuring
system
CAUTION
Due to the adjustment work required, the stroke measuring
•
system should only be changed by specialist personnel.
Different measuring systems are used in the drives. This operating
manual describes two measuring systems.
• LE 100
• TTK70
For more information on the optical stroke measuring systems,
refer to the separate operating manuals.
The LE 100 measuring system is a non-contact incremental
measuring system. In conjunction with the measuring tape in the
SCHUNK axes, the sensor head supplies a sin/cos signal and a
periodically recurring reference signal.
Measuring system modules
1
Reading head LE 100
3
Marking on magnetic strip 4
5
Covering tape
07.00 | LDH and LDK | Assembly and Operating Manual | en | GAS360923
Maintenance and repair work
2
Magnetic strip LE 100
Distance between reading
head and covering tape
129