Construction size
Max. hub [mm]
Nominal strengh [N] */**
Maximum strengh [N]
Repeatability [mm]
Max. standstill current [A
eff]
Maximum current [A eff]
Winding resistance at
25°C Z [Ohm]
Max. intermediate circuit
voltage [V]
Ambient temperature
max. [°C]
Ambient temperature
min. [°C]
Surface temperature max.
[°]
Impermeability IP
Pressurising medium:
compressed air - quality
Pressurising medium:
compressed air min/max
[bar]
Noise emission [dB(A)]

3 Technical Data

LDH-US-0050 |
LDH-ES-0050
200
52
125
±0,01
1,86
9,5
5,25
* Above an installation altitude of 1000 metres above sea level the
technical data is reduced.
** Depending on the situation of installation (heat dissipation) and
at 20°C ambient temperature.
Guarantee
Construction size
Length of guarantee [months]
or maximum mileage [km]
or maximum cycles [units]
Further technical data contain the catalogue data sheets. The most
recent version is valid.
07.00 | LDH and LDK | Assembly and Operating Manual | en | GAS360923
LDK-ES-0100 |
LDK-US-0100
400
115
250
±0,01
1,98
7,5
7,6
750
40
10
70
00
ISO 8573-1:7 4 4
5-7
≤ 70
LDH
24
20.000
50.000.000
Technical Data
LDK-EL-0200 |
LDK-UL-0200
300
185
500
±0,01
3,19
15
3,8
LDK
24
20.000
50.000.000