BTL7-V50E-M _ _ _ _ -A/B/Y/Z(8)-C003
Micropulse Transducer - Rod Style
3

Construction and function

...-B/Z...
8
11.5
1) Unusable area
2) Not included in scope of delivery
Version
D1
...-A/B/Y/Z-...
10.2 mm
...-A8/B8/Y8/Z8-...
8 mm
Fig. 3-1:
BTL7... transducer, construction
3.1
Construction
Electrical connection: The electrical connection is made
via a connector (see Type code breakdown on page 18).
BTL housing: Aluminum housing containing the
processing electronics.
Mounting thread: We recommend assembling these
transducers on the mounting thread:
BTL7-...-A/B: M18×1.5
BTL7-...-Y/Z: 3/4"-16UNF
The transducer with Ø 10.2 mm has an additional thread
at the end of the rod to support larger nominal lengths.
Magnet: Defines the position to be measured on the
waveguide. Magnets are available in various models and
must be ordered separately (see Accessories on
page 15).
The distance (L) between the magnets must be at least
65 mm.
Fig. 3-2:
Distance between the magnets
www.balluff.com
All manuals and user guides at all-guides.com
Mounting surface
B: 30-1 mm
Z: 2"-0.04"
0.5 Ø 25
109
25
G
Thread M4x4/6 deep
No thread
L
Damping zone
Nominal length =
Measuring range
2)
Magnet
Thread size
B: M18×1.5
Z: 3/4"-16UNF
Mounting surface
...-A/Y...
Nominal length: Defines the available measuring range.
Rods with various nominal lengths from 25 mm to
7620 mm are available depending on the version:
Ø 10.2 mm: Nominal length from 25 mm to 7620 mm
Ø 8 mm: Nominal length from 25 mm to 1016 mm
Damping zone: Area at the end of the rod that cannot be
used for measurements, but which may be passed over.
1)
45.2
60
46
A: 30-1 mm
Y: 2"-0.04"
Thread size
A: M18x1.5
109
25
Y: 3/4"-16UNF
english