BTL BNC_ 00- _ _ _ _ -B15A _010-000S92 / BTL ZNC_ 00- _ _ _ _ -B15A _010-000S92
Magnetostrictive Linear Position Sensor – Rod Style
4

Product description

Mounting surface
1)
X
0.5 Ø 25
25
10.5
34
Unusable area
1)
Not included in scope of delivery
2)
Fig. 4-1:
Dimensions, design and function
4.1

Construction

Electrical connection: The electrical connection is made
via a connector (see Type code on page 18).
Housing: Housing containing the processing electronics.
Fastening: We recommend assembling the following
BTLs on the mounting thread:
BTL B...: M18×1.5
BTL Z...: 3/4"-16UNF
BTL _NCA..., BTL _NCE... and BTL _NCJ... have an
additional thread at the end of the rod to provide support
for long measuring lengths.
Magnet: Defines the position to be measured on the
waveguide. Magnets are available in various models and
must be ordered separately (see Accessories on
page 17).
Measuring length: Defines the travel/length range
available. Sensors with measuring lengths from 25 mm to
4000 mm are available.
www.balluff.com
Null point
Measuring length
2)
Magnet
Thread size:
BTL B...: M18×1.5
BTL Z...: 3/4"-16UNF
End point
1)
60
Rod end
Type
X
BTL _NCA...
30 −1 mm
with thread M4/4.5 deep
BTL _NCE...
2" −0.04"
with thread M4/4.5 deep
BTL _NCC...
30 −1 mm
No thread
BTL _NCG...
2" −0.04"
No thread
BTL _NCJ...
40 −1 mm
with thread M4/4.5 deep
BTL _NCL...
40 −1 mm
No thread
4.2

Function

To determine the position of a plant component, a magnet
is connected to the component. Together they are moved
along a waveguide located inside the BTL.
An internally generated INIT pulse interacts with the
magnetic field of the magnet to generate a torsional wave
in the waveguide which propagates at ultrasonic velocity.
The component of the torsional wave which arrives at the
end of the waveguide is absorbed in the damping zone to
prevent reflection. The component of the torsional wave
which arrives at the beginning of the waveguide is
converted by a coil into an electrical signal. The position of
the magnet and thus at the same time that of the plant
component is determined from the running time of the
shaft.
Depending on the version, the position is output as a
voltage or current value with rising or falling gradient.
4.3

Part label

3)
Order code
Type
4)
Serial number
5)
Fig. 4-2:
Part label (example)
Ø45