BTL7-A/E501-M_ _ _ _-J-DEXC-TA12
Magnetostrictive Linear Position Sensor – Rod Style
7
Adjust with the calibration device (continued)
Output gradient
Rising
BTL7-A...
(output 1)
BTL7-E...
Falling
BTL7-A...
(output 2)
BTL7-E...
Tab. 7-1:
Factory settings value table
7.3

Calibration procedure overview

7.3.1

Teach-in

The detailed procedure for teach-in is described
on page 21.
The factory-set null point and end point are replaced by a
new null point and end point. The null point and end point
can be set separately, the output gradient changes.
Steps
► Move magnet to the new null position.
► Read new null point by pressing the buttons.
⇒ The current end point remains the same.
New null point
Fig. 7-1:
Reading new null point
► Move magnet to the new end position.
► Read new end point by pressing the buttons.
⇒ The current null point remains the same.
www.balluff.com
Null point
BTL
Unit
Min. value
V
−0.5
mA
V
+10.5
mA
20.4
Before
After
Type of protection "db" and "t"
Null value
End value
0
+10.0
3.6
4.0
20.0
+10.0
20.0
Before
After
Fig. 7-2:
Reading new end point
► The curves can be inverted by actuating the button.
⇒ Inverting inverts the curves of both outputs. For
example, a rising curve for output 1 is changed to a
falling curve and a falling curve from output 2 is
changed to a rising curve.
Flameproof enclosure
End point
Max. value
Error
value
+10.5
+10.5
20.4
3.6
0
−0.5
−0.5
4.0
3.6
3.6
New end point
New measuring length 100%
english
19