Herunterladen Inhalt Inhalt Diese Seite drucken

Calibration Procedure; Calibration Device; Programming Inputs (Not For Btl7; Calibration Procedure Overview - Balluff BTL7-A Serie Betriebsanleitung

Magnetostriktives positionsmesssystem; bauform stab
Vorschau ausblenden Andere Handbücher für BTL7-A Serie:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
BTL7-A/C/E/G _ _ _ -M _ _ _ _ -A(8)-SA211/SA311-S32/S115/S135/KA_ _/FA_ _
Magnetostrictive Linear Position Sensor – Rod Style
6

Calibration procedure

6.1

Calibration device

The calibration device is an additional device for calibrating
the BTL.
► Before calibrating: Place the calibration device on the
connection side of the BTL.
► When finished with calibration: Remove the calibration
device to prevent changes.
► Keep the calibration device for later use.
Automatic deactivation!
If the buttons on the calibration device are not
pressed for approx. 10 min,
programming mode is automatically ended.
Button 1 (blue)
Figure 6-1:
Calibration device in place
6.2
Programming inputs
(not for BTL7-...-S135)
Instead of the calibration device, the programming inputs
may also be used for setup.
La corresponds to button 1,
Lb corresponds to button 2,
Programming input at 20 to 28 V (BTL7-_1_ _-...) or
10 to 30 V (BTL7-_5_ _-...) corresponds to button
depressed (high active).
Automatic deactivation!
If no signals are transmitted via the
programming inputs for approx. 10 min,
programming mode is automatically ended.
14
english
Button 2 (gray)
6.3

Calibration procedure overview

6.3.1
Teach-in
The factory-set zero point and end point are replaced by a
new zero point and end point.
The detailed procedure for teach-in is described
on page 17.
Steps:
► Move magnet to the new null position.
► Read new zero point by pressing the buttons.
New zero point
Figure 6-2:
Reading new zero point (offset shift)
► Move magnet to the new end position.
► Read new end point by pressing the buttons.
Before
After
New measuring length 100%
Figure 6-3:
Reading new end point (changing the output gradient)
Before
After
New end point