Verfügbare Sprachen

8. Clean the drain pump filter carefully.
9. Depending on model, check that the pump rotor can move freely.
10. Insert the drain pump filter (C) and screw it in as far as possible in clockwise
direction (s. fig. below).
C
11. Check that the drain pump filter is installed properly.
12. Reinstall the cover panel properly.

7.3 Residual water drainage

1. Switch off the appliance and disconnect it from the mains.
2. Remove the cover panel of the drain pump filter; s. chapter 7.2 C
R
EMOVING OF THE DRAIN PUMP FILTER
3. Place a container in front of the opening.
4. Open the drain pump filter, but do not remove it completely. Rotate the drain
pump filter in anti-clockwise direction until the water begins to run.
5. Wait until the water has drained completely.
6. Unscrew the drain pump filter completely and remove it.
7. Carefully tilt the appliance forward so the water can be drained.
8. Insert the drain pump filter and screw it in as far as possible in clockwise direction.
9. Check that the drain pump filter is installed properly.
10. Reinstall the cover panel properly.
WARNING! Ensure before residual water drainage that the water has
cooled down completely. RISK OF SCALDING! RISK OF BURNS!
Fig. similar: fig. serve as an example only.