5.3 Residual water drainage

1. Switch off the appliance is disconnect it from the mains.
2. Remove the cover panel of the drain pump filter.
3. Place a container in front of the opening.
4. Open the drain pump filter, but do not remove it completely. Rotate the drain
pump filter in anti-clockwise direction until the water begins to run.
5. Wait until the water has drained completely.
6. Unscrew the drain pump filter completely and remove it.
7. Carefully tilt the appliance forward so the water can be drained.
8. Insert the drain pump filter and screw it in as far as possible in clockwise
direction.
9. Check that the drain pump filter is installed properly.
10. Install the cover panel.
CAUTION! Ensure before residual water drainage that the water has
cooled down completely. RISK OF SCALDING! RISK OF BURNS!

5.4 Cleaning of the water inlet valve

 The water inlet valve has to be cleaned, when it is not or improperly supplied
with water with the tap opened.
1. Close the water tap.
2. Disconnect the appliance from the mains (unplug).
3. Remove the water inlet hose from the washing machine.
4. Remove the filter net from the water valve.
5. Clean the filter net using some water and a toothbrush.
6. Reinstall the filter net properly.
7. Reconnect the water inlet hose to the appliance again.