Herunterladen Inhalt Inhalt Diese Seite drucken

Filtration; Outlet Line - Interpump Group SS71 Betriebs- Und Wartungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 59
3. Completely airtight and constructed to ensure a perfectly
hermetic seal through time.
4. Prevent the pump from emptying when it is stopped,
including partial emptying.
5. Do not use 3 or 4-way hydraulic fittings, adapters, swivel
joints, etc. as they could jeopardize pump performance.
6. Do not install Venturi tubes or injectors for detergent
suction.
7. Avoid use of foot valves or other types of unidirectional
valves.
9.7

Filtration

1 filter must be installed on the pump suction line, positioned as indicated in Fig. 7 and Fig. 7/a.
With fluid at ambient temperature
Inlet
Supply tank
With fluid at high temperature max. 85° C
Inlet
Supply tank
The filter, which is to be installed as close to the pump as
possible, must be easily inspectable and have the following
specifications:
1. Minimum flow rate at least 3 times the nominal flow rate
of the pump.
2. Inlet/outlet port diameters no smaller than the inlet port
diameter of the pump.
3. Filtration grade between 200 and 360 µm .
8. Do not recirculate the by-pass valve drain directly to the
suction line.
9. Provide for proper guards inside the tank to prevent that
water flow from the bypass and the tank supply line can
create vortexes or turbulence near the pump supply pipe
port.
10. Make sure the suction line is thoroughly clean inside
before connecting it to the pump.
1 Filter 1
2 Plunger pump
3 Pressure gauge
4 Safety valve
5 Manual control valve
Bypass
1 Filter
2 Booster Pump
3 Pressure gauge
4 Pressure switch
5 Plunger pump
Bypass
For smooth pump operation, regular filter
cleaning is necessary, planned according to the
actual use of the pump in relation to the quality
of water used and actual clogging conditions.
9.8

Outlet line

For correct design of the outlet line comply with the following
installation prescriptions:
1. The internal diameter of the pipe must be sufficient to
ensure correct fluid velocity, see graph in par. 9.9.
27
6 Pressure gauge
7 Safety valve
8 Manual control valve
Fig. 7
Fig. 7/a

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Sn71Sw71

Inhaltsverzeichnis