Herunterladen Inhalt Inhalt Diese Seite drucken

Installing The Ofl3.0 To The Router Table; Preparing Individual Router Tables - Sauter OFL3.0 Betriebsanleitung

Vorschau ausblenden Andere Handbücher für OFL3.0:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

8. Installing the OFL3.0 to the Router Table

8.1 Preparing individual Router Tables

(Skip this step if fixing to sauter routing tables FT)
Make the cut-out in your routing table according to the plan on page 28. Make sure the-
re is at least 15 mm rebate to rest the lift on. Make sure that the lift plate is aligned
flush with your table. Step-by-step instructions are given below. Optional accessories are
also available (see „Accessories").
Fig. 4 Required installation
dimensions on the
routing table
(enlarged view page 28)
8.1.1 Method 1 - Routing of a support rebate with the sauter routing template
(Art.Nr. SA-ELP-FS) and rebate cutter (Art.Nr. E-11651)
(optional accessory)
1) Position the template at the desired location on the routing table top.
2) Mark a rectangle inside the template, which is 15 mm smaller on each side. (for the
rebate = supporting surface for the insert plate).
3) Rout out completely the area marked on the router table top. For thicker panels, per-
form the routing in several steps.
4) Firmly attach the template to the routing table, set the depth of the router cutter
to 9,3 mm, add the template thickness, and rout with the ball bearing on the template
along the cutout.
5) Check that the rebate is deep enough. The insertion plate must be slightly below the
table top level.
6) Place the OFL with the mounted router motor into the cut-out and fasten it through
the provided mounting holes with the supplied threaded screws.