8.3 Leveling the OFL 3.0 in the Router Table
When the router lift is located in the recess of the table, tighten the fastening screws
in the corners. If there is minimal gap, loosen the screws a little and then use the
leveling screws
make sure. Tighten the fixing screws again and check. Repeat the procedure until a
perfectly flush fit is achieved

8.4 Leveling of the reduction plates in OFL3.0 in the milling table

If necessary, the reduction plates can be adjusted using leveling discs which can be
purchased separately (see "Accessories"),each with a disc thickness of 0.1 mm, also
the flatness of the magnetic reducing plates
corrected to prevent tilting of the plate.
9. Mounting the Safety Guard
In order to prevent the operator from unintentionally interfering with the router lift
during operation, the enclosed safety guard must be attached underneath the front of
the table. It must be screwed into the table plate from below.
(4) to get a flush fit. If necessary, check with a straightedge to
(5) within the insert plate can be
17
Fig. 5 Safety Guard