Installing In Flow Assemblies - Endress+Hauser CUS 5 Montage- Und Betriebsanleitung

Trübungsgrenzdetektor
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Turbidity sensor CUS 5
3.3

Installing in flow assemblies

CUA 250-A / CUA 250-B
• Run the connection cable
through the union nut
, the sleeve
the hexagonal gland
without twisting.
• Insert the sensor body into the sensor
sleeve
such that the O-ring comes to
rest under the internal G 1'' thread in the
sleeve
.
• Screw on the hexagonal gland
sensor thread and leave it loose so that the
sensor can still be turned for positioning.
Note:
Heed the notices on the following
pages for sensor adjustment.
• Tighten the gland
hand-tight after
adjusting the sensor.
Spray head CUR 3-1 (accessory)
• Screw the spray head CUR 3-1 into the
CUA 250 in place of the dummy plug
(see fig. 3.3).
Endress+Hauser
with plug
and
onto the
∅58
71
∅58
142
264
∅58
142
3.
Installation
13US005A.CHP
Fig. 3.2
CUA 250-A/-B
with spray head CUR 3-1
Connection cable
Hexagonal gland
Sleeve
Union nut
Marking hole
AD10 fitting
Pin
Slot
Spray head CUR 3
Fig. 3.3
CUA 250-A
with screwed adhesive
fitting DN 25
Connection cable
Hexagonal gland
Sleeve
Union nut
Dummy plug
Fig. 3.4
CUA 250-B prepared for
adhesive fitting DN 63
21