EN
A distance ≥ 0.3 m between the prod-
uct and the wall is recommended as a
working space for activating the main
power switch.
For stationary operation of the prod-
uct, install the hoses in such a way
that the product can be moved for-
ward for maintenance and servicing
purposes.
The water inlet is marked with IN [15].
The water outlet (for permeate) is marked with
OUT [14].
14
15
Connect the product with the connection
f
hoses:
1. Connect the inlet water hose to the drinking
water system connection and to the IN con-
nection [15] on the product and ensure it is
watertight.
2. Connect the outlet water hose to the OUT
connection [14] on the product.
6 .3
Establishing a sewage system
connection
As per DIN EN 1717, the waste water
hose must be connected to the drain
system connection at least 20 mm
above the highest possible waste wa-
ter level (unimpeded drainage).
Connect the waste water hose [4] to the rear
f
of the product and ensure it is watertight.
40
Guide the waste water hose to the connec-
f
tion for the waste water drain system with
the free outlet.
Connect the waste water hose to the waste
f
water drain system and secure the hose
from "wagging".
4
6 .4

Establishing the electrical supply

The following conditions must be met:
DA Schuko socket for plug type F is available at
the place of use.
DANGER!

Mains voltage!

Risk of death by electric shock!
► Operate the product only with the values spec-
ified in the technical data.
► Work on electrical product equipment must be
performed only by qualified electricians.
► Protect the product against the effect of hu-
midity and unauthorised modifications of the
mechanical or electrical components.
► If the mains cable of the product becomes
damaged, you must replace it with an original
BWT cable.
The product must be connected to a
residual-current device (RCD) with a
rated tripping current that does not ex-
ceed 30 mA.
There is a mains plug with a main power switch [16]
on the rear of the product. The length of the con-
nection cable [17] is 4 metres.