Start-up

The following conditions must be met:
DBoth membrane cartridges are installed.
DThe product is correctly connected to the
hydraulics system (see chapter „6.2 Produkt
anschließen", Seite 12).
DThe product is correctly connected to the
electrical system (see chapter „6.4 Elektrische
Versorgung herstellen", Seite 13).
NOTE
Damage to the product!
Product damage due to the impact of pressure from
the heating system
► Before startup, first open the check valve that is upstream
from the product.
► After connecting the outlet water hose, open the check
valve that is downstream from the product.
The product must be commissioned only by qua-
lified staff (see chapter „1.3 Qualifikation des Per-
sonals", Seite 4).
During commissioning and after replacing the
membrane cartridges, the outlet water hose must
first be guided into the waste water drain system
and a watertight connection with the system to be
filled must be re-established only after thorough rin-
sing (approx. 60 seconds).
10

Operation

NOTE
Product damage!
Damage to the product due to the impact of pressure
from the heating system
► Before startup, open the check valve that is upstream from
the product.
► After connecting the outlet water hose, open the check
valve that is downstream from the product.
NOTE
Damage to property!
Damage to property due to escaping water
► Always operate the product under observation.
► Check on a regular basis that connections and hoses are
leak-tight.
NOTE
Damage to the product and system!
Damage to the product and/or system due to microbial
contamination
► Operate the product or trigger rinsing at least once every
two weeks.
During initial commissioning and after
replacing the membrane cartridges,
rinse the product for approx. 60 se-
conds. Guide the outlet water into a
waste water drain system.
Check on a regular basis that all water
connections are leak-tight.
1. Open the check valve positioned upstream
from the product.
2. Guide the outlet water hose to the waste
water drain system first.
3. Press the main power switch on the rear of
the product. The product emits a signal tone
and the display lights up. The product starts
a self-test.
Following the self-test, pause mode is
automatically triggered in the product and
the LED indicator flashes green. The display
shows the main screen without the pump and
conductivity value.