Technical data
Designation
Nominal connection width
Pipe water connection
Connection for waste water
Connection for outlet water
Nominal pressure (PN)
Max. operating pressure
Inlet water supply pressure, min. – max.
Water temperature, min./max.
Ambient temperature, min./max.
Outlet water capacity at 15 °C with free discharge, at start of
service life
Outlet water capacity at 15 °C and 2.5 bar counter-pressure, at
start of service life.
Outlet water capacity at 15 °C with free discharge, at end of ser-
vice life, approx.
Outlet water capacity at 15 °C and 2.5 bar counter-pressure, at
end of service life, approx.
Outlet water conversion factor
Salt retention rate, min.
Capacity per membrane cartridge
Protection class
Power supply
Connected load, max.
External fuse
Pump capacity
High-pressure pump motor capacity.
54
Unit/type
AQA therm MOVE Power
DN/inch
DN20 / 3/4"
DN
20
DN
DN
20
bar
PN10
bar
bar
1.5 – 4
°C
5 – 25
°C
5 – 40
l/h
Approx. 360
l/h
Approx. 320
l/h
300
l/h
250
%
< 50
%
95
m³
40
IP
54
V/Hz
230 / 50
W
450
A,
2 x 2.0
time-de-
lay
m³/h
0.8
W
350
6
9