The following operating methods are prohibited:
● Failure to adhere to the technical specifications
(see chapter „5.3 Inlet water", Seite 36)
● The use of unauthorised consumables and
spare parts
● The use of unauthorised sanitising agent
● Overdosage of authorised sanitising agent
● The use of unauthorised aggressive cleaning
agents (e.g. chlorine)
● High fluctuations in the inlet water pre-pressure
● Operation without a grounded mains plug (PE)
● Heavy fluctuations in the electrical mains
voltage
● Excessive product switching frequency be-
cause ON/OFF switching points are incorrectly
positioned or too close to each other
● Operation near direct heat sources or open
flame (e.g. radiators, exposure to sunlight)
● Incorrect installation of the hoses (e.g. exces-
sive bends or a mechanical reducer)
● The use of desalinated outlet water as drinking
water
● Structural modifications to the product
● Covering the product
● Operating the product without the housing
● Reinstalling partly drained membrane cartridges
● Operating the product without monitoring it
5 .5

Fitting the wheels

1. Guide screw [9] from the inside out through
the strut and lock it with the supplied nut [10].
2. Attach the wheels [12] and secure them with
the supplied cap nut [11].
9
10
11
12
5 .6
Fitting the new membrane cart-
ridges
Replace the membrane cartridges
when the conductivity value of the
outlet water is ˃ 80 μS/cm, or every
3 years.
Always replace both membrane car-
tridges at the same time.
During initial commissioning and after
replacing the membrane cartridges,
rinse the product for approx. 60 sec-
onds. Guide the outlet water into a
drain.
To track the new membrane capac-
ity, reset the outlet water counter in
the BWT RO systems app and save.
40 m³ of water can be treated per
membrane cartridge.
1. Carefully tilt the product 90° to the rear.
2. Unscrew the old membrane cartridges from
the holder.
3. Carefully remove the cap from the mem-
brane cartridge.
4. Screw the new membrane cartridges [13]
into the holder and tighten them in their end
position by hand.
5. Reset the outlet water counter in the BWT
RO systems app.
EN