PRINT ?
PRINT xxx ?
PRINT xxx 0 or OFF
PRINT xxx 1 or ON
'R'
R
R1..500
RES X
RES ?
RS232 ?
RS232 bbbbb, NN, PP , SS
Code
RS485 ?
RS485 bbbbb, NN, PP , SS
RST
'S'
S
S10..2500
SET ?
SLA ?
SLA xxx
SN ?
STO ?
STO 0 or OFF
STO 1 or ON
Returns status of all print options
Option TXT :
Adds spaces to align output values (default ON)
Option XLS :
Adds a space in front of signed values (default ON)
Option SIGN : Replaces the + sign by a space (default ON)
Option TAB :
Adds a TAB between channels (default ON)
Option SP :
Adds a space between channels (default OFF)
Option CR :
Adds a CR between channels (default OFF)
Option LF :
Adds a LF after CR (default OFF)
Option CHA : Adds a CHAx: before the parameter (default OFF)
Option STO :
Clears the Hold function after each Print (default OFF)
Option DOT :
Uses the dot as decimal separator else comma (default DOT separator)
Option NAME xxxxxx : Adds the chanel name xxxxxx for each printed value (max 6
characters)
(Options TAB, SP and CR are mutually exclusive)
Returns status of print option xxx
Disables the print option xxx
Enables the print option xxx
Reads a chanel
Reads the memorized data's
Actives the resolution
X = 1 : 0.0001mm, 0.00001''
X = 3 : 0.01mm / 0.001''
X = 5 : 0.0005mm / 0.00005''
X = 7 : 0.0001mm / 0.00001'' user settings
X = 8 : 0.001mm / 0.0001'' user settings
Returns the resolution
Returns the USB port COM configuration.
Changes the USB port COM configuration. Baud rate bbbbb [4800..256000], Nb bits NN
[7B or 8B], Parity PP [PE or PO or P-], Stops bits SS [1S or 2S]
Function
Returns the RS485 port COM configuration.
Changes the RS485 port COM configuration. Baud rate bbbbb [4800..256000], Nb bits
NN [7B or 8B], Parity PP [PE or PO or P-], Stops bits SS [1S or 2S]
Reset the module (user parameters)
Activates the external contact for 500ms
Activates the external contact for n ms
Returns the configuration of the chanels (activated channel, measuring unit, Resolution,
Direction, Radius/Diameter, Mult Factor, Normal/Min/Max/Delta, locked channel)
Returns the Modbus address of the module (0 = unconfigured module)
Changes the Modbus address of the module (1...247 , 0 for address erasure)
Returns the serial number of the module (fixed parameter)
Returns the status of a channel
Unlocks a channel
Locks a channel
X = 2 : 0.001mm / 0.0001''
X = 4 : 0.1mm / 0.01''
X = 6 : 0.005mm / 0.0005''