Routing
12.5 Tracking
Ping Tracking Instance-----------------------------------
Name...........................................ping-21
Interface Number of outgoing ping packets......1/2
Target router network address..................10.0.2.53
Interval of missed repl. the state is down.....3
Interval of received repl. the state is up.....2
Maximal roundtrip-time ........................100
Time-To-Live for a transmitted ping request....128
Ifnumber which belongs to the best route.......
State..........................................down
Send State Change trap.........................disabled
Number of state changes........................0
Time of last change............................2014-06-18 14:23:22
Description....................................
show track ping 22
Ping Tracking Instance-----------------------------------
Name...........................................ping-22
Interface Number of outgoing ping packets......1/3
Target router network address..................10.0.2.54
Interval of missed repl. the state is down.....3
Interval of received repl. the state is up.....2
Maximal roundtrip-time ........................100
Time-To-Live for a transmitted ping request....128
Ifnumber which belongs to the best route.......
State..........................................up
Send State Change trap.........................disabled
Number of state changes........................0
Time of last change............................2014-06-18 14:23:55
Description....................................
show track logical 31
Logical Tracking Instance-----------------------------------
Name...........................................logical-31
Operand A......................................ping-21
Operand B......................................ping-22
Operator.......................................or
State..........................................up
Send State Change trap.........................disabled
Number of state changes........................0
Time of last change............................2014-06-18 14:24:25
Description....................................
Anwendungsbeispiel für Logical-Tracking
Die Abbildung
einem redundanten Ring.
Durch die Überwachung der Leitungen L 2 und L 4 können Sie die Verbindungsunterbrechung des
Routers A zum redundanten Ring erkennen.
Mit einem Ping-Tracking-Objekt auf dem Port
zum Gerät S2.
Mit einem zusätzlichen Ping-Tracking-Objekt auf dem Port
Verbindung zum Gerät S4.
184
(siehe Abbildung 45)
zeigt ein Beispiel für die Überwachung der Verbindung zu
Die konfigurierten Tracks anzeigen.
Die konfigurierten Tracks anzeigen.
des Routers A überwachen Sie die Verbindung
1/1
1/1
des Routers A überwachen Sie die
UM Config EAGLE
Release 03.5 08/2020

Werbung