The drill speeds specified are merely suggested
values.
Drill
Cast
Steel
Iron
bit ø
iron
3
2550
1600
2230
4
1900
1200
1680
5
1530
955
1340
6
1270
800
1100
7
1090
680
960
8
960
600
840
9
850
530
740
10
765
480
670
11
700
435
610
12
640
400
560
13
590
370
515
14
545
340
480
16
480
300
420
18
425
265
370
20
380
240
335
22
350
220
305
25
305
190
270
Countersinking and center-drilling
With this table drill, you can also countersink and
center-drill. Please observe that countersinking
should be performed at the lowest speed, while a
high speed is required for center-drilling.
Drilling wood
Please note that sawdust must be properly evacuated
when working with wood, as it can pose a health haz-
ard. Ensure that you wear a suitable dust mask when
performing work that generates dust.

10. Electrical connection

The electrical motor installed is connected and
ready for operation. The connection complies
with the applicable VDE and DIN provisions. The
customer's mains connection as well as the ex-
tension cable used must also comply with these
regulations.
Important information
In the event of overloading, the motor will switch itself
off. After a cool-down period (time varies) the motor
can be switched back on again.
Damaged electrical connection cable
The insulation on electrical connection cables is of-
ten damaged.
30 | GB
 www.scheppach.com /  service@scheppach.com /  +(49)-08223-4002-99 /  +(49)-08223-4002-58
Alumini-
Bronze
um
9500
8000
7200
6000
5700
4800
4800
4000
4100
3400
3600
3000
3200
2650
2860
2400
2600
2170
2400
2000
2200
1840
2000
1700
1800
1500
1600
1300
1400
1200
1300
1100
1150
950
This may have the following causes:
• Pressure points, where connection cables are
passed through windows or doors.
• Kinks where the connection cable has been im-
properly fastened or routed.
• Places where the connection cables have been cut
due to being driven over.
• Insulation damage due to being ripped out of the
wall outlet.
• Cracks due to the insulation ageing.
Such damaged electrical connection cables must not
be used and are life-threatening due to the insula-
tion damage.
Check the electrical connection cables for damage
regularly. Ensure that the connection cables are dis-
connected from electrical power when checking for
damage.
Electrical connection cables must comply with the
applicable VDE and DIN provisions. Only use con-
nection cables with the marking „H05VV-F".
The printing of the type designation on the connec-
tion cable is mandatory.
AC motor
• The mains voltage must be 230 V~
• Extension cables up to 25 m long must have a
cross-section of 1.5 mm
.
2
Connections and repairs of electrical equipment may
only be carried out by an electrician.
Please provide the following information in the event
of any enquiries:
• Type of current for the motor
• Machine data - type plate
• Machine data - type plate

11. Cleaning and maintenance

Pull the mains plug before any adjustments,
maintenance or repair.
m Have any work on the device that is not de-
scribed in this instruction guide performed by
a professional. Only use original parts. Allow
the device to cool off before any maintenance
or cleaning is undertaken. There is a risk of burn-
ing!
Always check the device before using it for obvi-
ous defects such as loose, worn or damaged parts,
correct the positioning of screws or other parts. Ex-
change the damaged parts.
Cleaning
Do not use any cleaning agents or solvents. Chemi-
cal substances could damage the plastic parts of the
device. Never clean the device under running water.

Quicklinks ausblenden: