Herunterladen Inhalt Inhalt Diese Seite drucken

Electrical Connection; Maintenance - Scheppach Basa 5.0 Originalanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
evenly using both hands with the fingers together.
Hold the workpiece with your hands on a safe
area.
• Use a pattern for repeated arced or irregular cuts.
• Insure that the workpiece does not roll when
cutting round pieces.
 The installed electric motor is connected
and is ready to work.
The connection complies with the relevant VDE
and DIN regulations.
The customer-side mains supply and the used
extension line must meet these regulations.
Installations, repair, and maintenance work
relating to the electric installation may only be
performed by specialists.
Important Notes
The electric motor has been designed for the S 1
operating mode.
In case of an overload of the motor, it turns off
automatically. After a cooling period (duration
varies), you can turn on the motor again.
 Defective Electric
Connection Lines
Often, insulation damages occur on electrical
connection lines.
Causes are:
1. Drag marks if connection lines are led through
window or door clearances.
2. Kinks due to improper attachment or routing of
the connection line.
3. Cuts caused by running over the connection
line.
4. Insulation damages caused by pulling the con-
nection line out of the wall socket.
5. Fissures caused by the ageing of the insulation.
Such defective electric connection lines must
not be used and are hazardous due to the
insulation damages.
Regularly check the electrical connection lines for
damages. Please make sure that the connection
Carry out refitting, setting measurement and
cleaning work only when the motor is switched
off. Pull the plug and wait for the sawband to
come to a full stop.
An experience worker can carry out minor-
repairs on the machine himself.
Electrical Connection 

Maintenance

• Use the traverse cutting gauge special acces-
sory for safety when making traverse cuts.
• To safely cut round plates, use the circular cut-
ting unit special accessory.
lines are disconnected from the mains supply
during the check.
Electrical connection lines must comply with the
relevant VDE and DIN regulations. Only use con-
nection lines labelled with H 07 RN. The labelling
of the connection cable with the type specification
is required.
AC motor
1. The supply voltage must be 230 V / 50 Hz.
2. Extension lines up to a length of 25 m must
have a cross section of 1.5 square millimetres.
Extension lines with a length of more than 25
m must have a minimum cross section of 2.5
square millimetres.
3. The mains connection is protected with a delay-
action fuse of 16 A.
Rotary current motor
1. The supply voltage must be 400 V / 50 Hz.
2. Mains supply and extension line must be five-
wire = 3 P + N + SL.
3. Extension lines must have a minimum cross
section of 1.5 square millimetres.
4. The mains connection is protected with a maxi-
mum of 16 A.
5. In case of mains supply or change of location,
the direction of rotation must be checked. If
required, the polarity must be reversed.
If you have further questions, please specify
the following:
1. Motor manufacturer
2. Kind of current of the motor
3. Data from the machine type plate
4. Data from the switch type plate
If you return the motor, always return the com-
plete drive unit with the switch.
Repair and maintenance work on the electrical
system may only be carried out by a qualified
electrician.
All protective and safety devices must be re-
attached immediately after completed repair
and maintenance work.
GB
GB

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

19015059011901505902

Inhaltsverzeichnis