Operating instructions for the user - Figure 8
1
For your safety
The error messages mean:
ERR 1:
Overtemperature fuse F I is defective
ERR 2:
Internal error of the control
ERR 3:
Broken F I line
ERR 4:
Short circuit of line F I
ERR 5:
Short circuit of line FII
ERR 6:
Interruption of line F II
2
Turning the interior lighting on/off
NOTE:
The interior lighting can be turned on/off independent of
the control function.
1. Use button 4 to turn the sauna interior lighting
ON / OFF, if the ON / OFF switch 1 is turned ON.
If the interior lighting is turned on, the signal lamp
button 4 will light up.
2. Switch 2 on the control unit turns the interior ligh-
ting ON / OFF independent of the ON / OFF switch
1. There is no acknowledging signal to the sig-
nal lamp button 4.
NOTE:
The light switch 2 and the light pushbutton 4 are shun-
ted, so that if the switch is ON, you won't be able to use
the pushbutton to turn OFF the interior lighting and vice
versa.