Herunterladen Inhalt Inhalt Diese Seite drucken

General Safety Information; For Your Safety - Sentiotec CV 4 Gebrauchsanweisung

Sauna steuerungen
Vorschau ausblenden Andere Handbücher für CV 4:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Operating instructions for the user 8

General safety information

Please also observe the particular safety informa-
tion provided in the individual chapters.
WARNING - Fire hazard:
Prior to turning on the sauna control and
when selecting the start-time (time until the
stove starts) make sure that no combustib-
le objects have been placed on top of the
stove.
Versions CV 4 and CV F4:
With the exception of the color light selection of CV F4,
the sauna controls CV 4 and CV F4 are identical in
function and operation.
Intended purpose:
• The purpose of the sauna controls CV 4 and CV F4
is to control the functions according to the techni-
cal data (last page).
• You may only use the sauna controls CV 4 and
CVF4 for controlling 3 heating circuits with a maxi-
mum heating capacity of 3.5 kW per heating circuit.
• As an option, you can increase the switching capa-
city with an additional power unit from 10.5 kW to
18 kW / 30 kW.
• Only mount and operate the power supply unit with
the operating unit included in standard delivery.
32
1

For your safety

CAUTION - Damage to the unit:
Do not pour water on the operating unit of the sau-
na control or clean it with a wet cloth. For cleaning
please use a cleaning cloth that has been slightly
moistened with a mild, soapy solvent (dish deter-
gent).
WARNING - Fire hazard:
Prior to turning on the sauna control and
when selecting the automatic start-time (de-
layed turning on time) make sure that no
combustible objects have been placed on
top of the stove.
1
Measured values outside the measuring
range
Temperatures below 10° C in the sauna cabin are
indicated by "LL = Low" in the display. Temperatures
higher than 115° C are indicated by "HH = High" in the
display.
The sauna control will also continue to work proper-
ly outside of the measuring range.
2
ERROR messages
An ERROR message with a number in display 5 si-
gnalizes an electrical defect of the system.
The sauna control is no longer ready-to-operate:
1. Write down the ERROR number.
2. Shut off the main fuses of the sauna control in
the fuse box.
3
Contact customer service.
4
Mark the unit as "defective".
Using the following display error messages 5 you can
inform customer service of possible errors/defects.