Installation instructions for trained electricians only
6
Continued
Error description:
Relays wobble
Unit turns on too early.
Unit turns on too late.
Unit does not turn on at all.
Determined system deviation ____ °C.
The set temperature is not kept constant.
Disturbing sounds come from the control.
The interior lighting does not light.
The fan control (speed) is defective.
ERROR number___ is indicated on the display.
The temperature fuse has been triggered unex-
pectedly.
Heater is turned off
Error occurs immediately after turning on.
Error occurs after it has been turned on for a while.
Operating unit can not be operated as intended.
Miscellaneous:
______________________________________
______________________________________
______________________________________
______________________________________
7
Changing Light fuse, the optional
fan and the unit electronics -
Figure 1
WARNING - Electric shock
Disconnect all poles of the sauna control
from the mains and secure from unintentio-
nal switching on prior to opening the cover
of the housing.
1. Slightly push in safety lock 5 and remove the
cover of the housing 6.
2. Figure 2: Release six-pin flat strip wiring 3 and
remove from connector 2.
3. Carefully remove cover 2 from base of housing
7.
4. Fuse for interior lighting
Replace (miniature fuse 5x20 T2.0 A/ 250V) A or
fuse for fan
(subminiature fuse TR 5 - T 1.0 A/ 250V) 8 or
fuse for unit electronics
(miniature fuse 5x20 T630 mA/ 250V) B.
5. Insert strips 3 of cover 2 into both holding fix-
tures 4 on the sides and carefully push down on
the base of housing 7.
Check function of both switches C. (On and off
6
position)
7. Figure 2: Push six-pin flat wire strip 3 on con-
nector 2 until you can hear the lock lever snap
in position (lock lever points downwards).
8. Fit the housing cover 6 on the base of the hou-
sing 7, rotate it downwards and push down on
it until you can hear it lock in position.
Check for secure fit of housing cover.
29