RDE 92 750-01-R/03.03 | A10VG
Einstellhinweise - DA- Regelung
Adjustment instructions - DA control
Timing
adjustment screw
*
Begin of control
Mobile Hydraulics | Bosch Rexroth AG
Attention!
Observe safety regulations!
Check setting data.
Operating temperature should be generally kept
constant during the checking procedure.
Start prime mover, idle speed.
Block position
Drive direction switch - "0".
Slowly increase motor speed up to the max. motor
speed and observe measuring instruments.
Boost pressure:
Idle speed of prime mover
Psp = approx. 15 - 20 bar
max. motor speed
Psp = . . . . . . . . . bar*
Block position
Drive direction switch - forwards
(Road gear and fully applied brake)
Check setting data pump A4VIDA
*
Start of control:
HD 40 - 50 bar
Motor speed . . . . . rpm*
Psp . . . . . . . bar*
HD . . . . . . . bar*
Readjustment of start of control screw
End of control
HD . . . . . . . . bar
Motor speed . . . . . . rpm*
Psp . . . . . . . bar*
Readjustment of the indexing screw
Note:
Eccentric adjusting - observe direction of
rotation.
Note: * Setting data is in accordance to the
order work!
55