Maintenance / Repairs / Cleaning
– The appliance may only be repaired and
cleaned by an expert.
– Maintenance, repairs and cleaning must not
be done by children.
– Combi E only:
If this appliance's power supply line is dam-
aged, it must be replaced by the manufac-
turer, the manufacturer's Customer Service
or a similarly qualified person so as to pre-
vent hazards
.
– In particular, the following will render war-
ranty and guarantee claims void and lead to
exemption from liability claims:
– Modifications to the appliance (including
accessories),
– Modifications to the exhaust gas system
and the cowl,
– Using replacement and accessory parts
other than original Truma parts,
– Failure to follow the installation and
operating instructions.
The appliance's operating permit, and conse-
quently also the vehicle's operating permit in
some countries, are also rendered void.
– With a new Combi or if the appliance has not
been used for some time, thoroughly rinse
all hot / cold water hoses with drinking water
before use.

Function description (Combi)

The liquid gas heater Combi is a warm-air heater with inte-
grated hot water boiler (10 litre volume). The burner is fan-
assisted, which ensures that operation is problem-free, even
when on the move.
In heating mode, the heater can be used to heat both the
room and water simultaneously. If only hot water is required,
this is possible in hot water mode.
– In hot water mode, the water is heated at the lowest burner
setting. Once the water temperature has been reached, the
burner switches off.
– In heating mode the appliance automatically selects the
required operating level according to the temperature dif-
ference between the temperature set on the control panel
and the current room temperature. If the boiler has been
filled, the water is automatically heated as well. The water
temperature depends on the selected operating mode and
the heater output.
At a temperature of approximately 3 °C at the automatic
FrostControl safety / drain valve, the valve will open and drain
the boiler.
Function description(Combi E)
(in conjunction with the Truma CP plus control panel)
The liquid gas heater Combi E is a warm-air heater with inte-
grated hot water boiler (10 litres volume). The burner is fan-
assisted, which ensures that operation is problem-free, even
when on the move. The appliance also has heating elements
for electrical operation.
In heating mode, the heater can be used to heat both the
room and water simultaneously. If only hot water is required,
this is possible in hot water mode.
At a temperature of approximately 3 °C at the automatic
FrostControl safety / drain valve, the valve will open and
drain the boiler.
3 different options are available for operating the appliance:
– only gas mode
Propane / Butane for autonomous use
– only electric mode
230 V
for stationary use on camp sites
– or gas and electric mode — mixed mode
possible only in heating mode.