gefran 600 Bedienungsanleitung Seite 24

Vorschau ausblenden Andere Handbücher für 600:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 34
Downloaded from
www.Manualslib.com
l5. 2
xs. 2
of. 2
lo. l
xi. l
Out
a1. r
a2. r
a3. r
a1. t
a2. t
a3. t
xb. f
manuals search engine
Minimum limit auxiliary
0.0 ... 999.9
input scale
Maximum limit auxiliary
0.0 ... 999.9
input scale
Offset correction
-99.9 ... 99.9
of aux input
scale points
Lower limit for setting SP
Lo.S ... Hi.S
and absolute alarms
Upper limit for setting SP
Lo.S ... Hi.S
and absolute alarms
• Out
Output settings
Select
reference
signal for
alarm 1
AL.1.r, AL.2.r, AL.3.r
Select
AL.x.r
Variable to be compared
reference
0
PV (Process variable)
signal for
1
SSP (active setpoint)
alarm 2
2
PV (process variable)
Select
reference
signal for
alarm 3
AL.1.t, AL.2.t, AL.3.t
AL.x.t
Direct (high limit)
Absolute or
Alarm
Inverse (low limit)
relative to
type 1
active setpoint
0
direct
absolute
1
inverse
absolute
Alarm
2
direct
relative
type 2
3
inverse
relative
4
direct
absolute
5
inverse
absolute
6
direct
relative
Alarm
7
inverse
relative
type 3
+8 to disable on power up until first interception
+16 to latch alarm
+ 32 Hys becomes delay time when alarm trips (0...999 sec.) (excluding symmetrical absolute)
+ 64 Hys becomes delay time when alarm trips (0...999 min.) (excluding symmetrical absolute)
Val.
Function description
HB alarm
0
Relay, logic output: alarm active
function
on load current level lower
than setpoint during the
ON time of the control output
1
Relay, logic output: alarm active
on load current level higher
than setpoint during the
OFF time of the control output
2
Alarm active if one of functions 0 and 1
is true (OR logic between 0 and 1) (*)
3
Continuous heat alarm (**)
7
Continuous cool alarm (**)
+ 0
assigned to Out1 (only for Hb_F= 0, 1, 2)
+ 4
assigned to Out2 (only for Hb_F= 0, 1, 2)
+ 12 assigned to Out4 (only for Hb_F= 0, 1, 2)
+16
inverse HB alarm
Notes:
- The HB alarm is disabled if assigned to a rapid output (except codes 3 and 7)
- When the CT input is present, faceplate LED OUT3 always indicates the state of the HB alarm.
(*) minimum setting is fixed at 12% of amperometric full scale
(**) As type 0 without reference to cycle time
24
Reference setpoint
AL
AL (only absolute)
AL (only relative and
referred to SP1 with
multiset function)]
Normal
Symmetrical
(window)
normal
normal
normal
normal
symmetrical
symmetrical
symmetrical
symmetrical