Herunterladen Inhalt Inhalt Diese Seite drucken

gefran 600 Bedienungsanleitung Seite 23

Vorschau ausblenden Andere Handbücher für 600:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 34
s. i n
InP
sp. r
typ.
Type
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
For custom linearization:
- LO signal is generated with variable below Lo.S or at minimum calibration
value
- HI signal is generated with variable above Lo.S or at maximum calibration
value
Downloaded from
www.Manualslib.com
Virtual instrument
0 ... 31
inputs
Inputs
IN
PV
AL3
AL2
AL1
Bit
4
3
2
1
Ex:
1
1
0
0
Set code 24 in S.in. to manage serial line AN and
IN
• InP
Input settings
Val. Type of remote setpoint Absolute Relative
Def. remote setpoint
0
Digital
(from serial line)
1
Digital
(from serial line)
+2 set gradient in digit / sec
Probe type, signal, enable custom linearization,
and main input scale
Probe type
without decimal point
with decimal point
Sensore:
TC
TC J °C
0/1000
TC J °F
32/1832
TC K °C
0/1300
TC K °F
32/2372
TC R °C
0/1750
TC R °F
32/3182
TC S °C
0/1750
TC S ° F
32/3182
TC T °C
-200/400
TC T °F
-328/752
TC B °C
44/1800
TC B °F
111/3272
TC E °C
-100/750
TC E °F
-148/1382
TC N °C
0/1300
TC N °F
32/2372
L-GOST °C
0/600
L-GOST °F
32/1112
TC U °C
-200/400
TC U °F
-328/752
TC G °C
0/2300
TC G °F
32/4172
TC D °C
0/2300
TC D °F
32/4172
TC C °C
0/2300
TC C °F
32/4172
Ni-Ni18Mo °C
0/1100
Ni-Ni18Mo °F
32/2012
TC
CUSTOM
TC
CUSTOM
PT100 °C
-200/850
PT100 °F
-328/156 2
JPT100 °C
-200/600
JPT100 °F
-328/1112
PTC °C
-55/120
PTC °F
-67/248
NTC °C
-10/70
NTC °F
14/158
0...60 mV
-1999/9999
0...60 mV
Custom scale
12...60 mV
-1999/9999
12...60 mV
Custom scale
0...20 mA
-1999/9999
0...20 mA
Custom scale
4...20 mA
-1999/9999
4...20 mA
Custom scale
0...10 V
-1999/9999
0...10 V
Custom scale
2...10 V
-1999/9999
2...10 V
Custom scale
0...5 V
-1999/9999
0...5 V
Custom scale
1...5 V
-1999/9999
1...5 V
Custom scale
0...1 V
-1999/9999
0...1 V
Custom scale
200mv..1V
-1999/9999
200mv..1V
Custom scale
Cust10 V-20mA
-1999/9999
Cust10 V-20mA
Custom scale
Cust 60mV
-1999/9999
Cust 60mV
Custom scale
PT100-JPT
CUSTOM
PTC
CUSTOM
NTC
CUSTOM
manuals search engine
s. 0 v
0
0
s. U . i
Interf. LED
Bit
Ex:
If you want to manage KEYB and DISH from serial line, set code 80 in
Absolute
S.U.I.
Reletive to
local setpoint
Max. non-linearity error for
thermocouples (TC),
resistors (PT100) and
thermistors (PTC, NTC).
0.0/999.9
32.0/999.9
The error is calculated as
deviation from theoretical
0.0/999.9
value and is expressed as
32.0/999.9
percentage of full scale (in
0.0/999.9
°C).
32.0/999.9
0.0/999.9
32.0/999.9
-199.9/400.0
-199.9/752.0
44.0/999.9
111.0/999.9
-100.0/750.0
-148.0/999.9
0.0/999.9
32.0/999.9
0.0/600.0
32.0/999.9
flt
-199.9/400.0
-199.9/752.0
0.0/999.9
32.0/999.9
0.0/999.9
fld
32.0/999.9
0.0/999.9
32.0/999.9
0.0/999.9
32.0/999.9
CUSTOM
CUSTOM
dp. s
-199.9/850.0
-199.9/999.9
-199.9/600.0
-199.9/999.9
-55.0/120.0
-67.0/248.0
-10.0/70.0
14.0/158.0
-199.9/999.9
lo. s
Custom scale
-199.9/999.9
Custom scale
-199.9/999.9
Custom scale
-199.9/999.9
xi. s
Custom scale
-199.9/999.9
Custom scale
-199.9/999.9
Custom scale
-199.9/999.9
Custom scale
ofs.
-199.9/999.9
Custom scale
-199.9/999.9
Custom scale
-199.9/999.9
Custom scale
ft. 2
-199.9/999.9
Custom scale
-199.9/999.9
Custom scale
CUSTOM
CUSTOM
CUSTOM
23
Virtual instrument
0 ... 31
outputs
Outputs
OUTW OUT4
OUT3
OUT2
Bit
4
3
2
Ex:
1
0
0
set code 19 in S.Ou. to manage serial line OUT1, OUT2
and OUTW.
Virtual instrument user
0 ... 63
interface
KEYB
DISL
DISH
LED
LED
1/2/3
OUT4
OUT3
7
6
5
4
3
2
1
0
1
0
0
S, R range 0...1750°C; error < 0.2% f.s. (t > 300°C) / for other
range; error < 0.5% f.s.
T
error < 0.2% f.s. (t > -150°C)
B
range 44...1800°C; error < 0.5% f.s. (t > 300°C) / range
44,0...999,9; error < 1% f.s. (t > 300°C)
U
range -99,9...99,9 and -99...99°C; error < 0.5% f.s. / for other
range; error < 0.2% f.s. (t > -150°C)
G
error < 0.2% f.s. (t > 300°C)
D
error < 0.2% f.s. (t > 200°C)
C
range 0...2300; error < 0.2% f.s. / for other range;
error < 0.5% f.s.
NTC error < 0.5% f.s.
Tc: J, K, E, N, L
error < 0,2% f.s.
JPT100 and PTC
error < 0,2% f.s.
PT100 scale -200...850°C
Precision better than 0,2% f.s. at 25°C
In range 0...50°C:
• Precision better than 0,2% f.s. in range -200...400°C
• Precision better than 0,4% f.s. in range +400...850°C
(where f.s. refers to range -200... +850°C)
Digital filter on input
(if = 0 excludes averaging filter on
0.0 ... 20.0 sec
sample value)
Digital filter on input
0 ... 9.9
display
scale points
dP_S
Format
0
xxxx
Decimal point position for
1
xxx.x
input scale
2
xx.xx (*)
3
x.xxx (*)
(*) not available for TC, RTD,
PTC and NTC scales
Minimum limit of main
min...max input range
input scale
selected in tyP
Maximum limit of main
min...max input range
input scale
selected in tyP
Offset correction
-999 ... 999
of main input
scale points
Digital filter
0.0 ... 20.0 sec
aux. input
OUT1
1
0
1
1
LED
LED
OUT2
OUT1
1
0
0

Werbung

Inhaltsverzeichnis
loading