Herunterladen Inhalt Inhalt Diese Seite drucken

gefran 600 Bedienungsanleitung Seite 19

Vorschau ausblenden Andere Handbücher für 600:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 34
Function indicators
Indicates modes of operation
MAN/AUTO
= OFF (automatic control)
SETPONT1/2 = OFF (IN1 = OFF - local Setpoint 1)
SELFTUNING = ON (enabled Self)
Automatic/Manual adjustment selection
Active only when PV display visualises
the process variable
Press to increment (decrement) any numerical parameter •• Increment (decrement) speed is
proportional to time key stays pressed •• The operation is not cyclic: once the maximum
(minimum) value of a field is reached, the value will not change even if the key remains pressed.
• Ammeter outputs/input
User configurable generic output
19
-
Out2
20
+
21
Out1
22
6
-
Out3 (Al2)
Ing. T.A.
5
+
• Power Supply
~
23
PWR
~
24
• Serial line / output 4
Modbus
A
9
(Data +)
10
B
(Data -)
11
Standard
configuration
RS485 isolated serial line
See serial card data sheet for Cencal configuration
SERIAL INTERFACE/OUT4
CPU
DISPLAY
Downloaded from
www.Manualslib.com
3 • DESCRIPTION OF FACEPLATE
ON (manual control)
ON (IN1 = ON - local Setpoint 2)
OFF (disabled Self)
"Inc" and "Dec" key
- 5A at 250Vac/30Vdc relay
- 24V, 10V at 20mA logic
- triac 20...240Vac, 1A ±10%
- 5A/250Vac relay only
- 5A at 250Vac/30vdc relay
- 24V, 10V at 20mA logic
- continuous 0...10V, 0/4...20mA
- analog 0...10V, 0/4...20mA for
transmission, resolution 12 bit
- input from current transformer
50mAac, 10 Ω 50/60 Hz
- logic input 24V, 5mA or from
!
no-voltage contac
Standard:
100...240Vac ± 10%
Optional:
20...27Vac/Vdc ± 10%
Max. power 8VA; 50/60 Hz
Cencal
Out 4
9
-
5A at 250Vac/30Vdc
TX
relay
10
+
11
-
11
RX
+
12
12
• Device structure
POWER
manuals search engine
4 • CONNECTIONS
TOP
19
18
7
6
20
17
8
5
21
16
9
4
22
15
10
3
23
14
11
2
24
13
12
1
• Linear input (I)
Linear
4
input in
dc
2
current
1
20mA,
Ri = 50Ω
• Linear input (V)
Linear input in
dc voltage
60mV, 1V
Ri > 1MΩ
5V, 10V
Ri > 10KΩ
Power board - Solder side
Select transmitter
voltage
N.B. : you can keep the OUT1 relay energized at power-up by
inserting jumper S2 and removing resistance R20.
CPU board - Component side
19
Indication of output states
OUT 1 (AL1); OUT 2 (Main); OUT 3 (HB); OUT 4 (HB)
PV Display: Indication of process variable
Error Indication: LO, HI, Sbr, Err
LO= the value of process variable is < di LO_S
HI= the value of process variable is > di HI_S
Sbr= faulty sensor or input values higher than max. limits
Err= PT100 third wire opened for PT100, PTC or input
values lower than min. limits (i.e.: TC wrong connection)
SV display: Indication of setpoint
Function key
Gives access to the various configuration phases ••
Confirms change of set parameters and browses next or
previous parameter (if Auto/Man key is pressed)
• Inputs
• TC Input
Available thermocouples:
J, K, R, S, T, B, E, N,
L, U, G, D, C
- Observe polarities
- For extensions, use the
correct compensating cable
for the type of TC used
• Linear input with 3-wire transmitter
Connect at 20mA input
4
VT
+
3
-
2
+
1
• Input 1 linear with transmitter 2 wires
4
-
+
VT
3
-
2
+
4...20mA
+
1
• Pt100 / PTC / NTC
Use wires of
3
2
adequate diameter
-
(min. 1mm
)
2
PT100, JPT100,
2
PTC, NTC
1
+
1
• Identification of boards
R20
S2
Select signal at
contact 3
-
2
1
+
24V o 15V
+
S
-
24V o 15V
+
-
T
T
PTC / NTC /
Pt100 3 wires
Pt100 2 wires
IN/OUT boards
(see appendix)

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis