Herunterladen Inhalt Inhalt Diese Seite drucken

Specifications - WIKA DELTA-comb DPGS40TA Betriebsanleitung

Vorschau ausblenden Andere Handbücher für DELTA-comb DPGS40TA:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

3. Specifications

3. Specifications
The insulation values (air gaps and creepage distances) are sized for the follow-
ing ambient conditions in accordance with EN 61010-1:2010:
EN
Altitude up to 2,000 m
Overvoltage category II
Pollution degree 2
Relative humidity 0 ... 95 % non-condensing (per DIN 40040)
The strength of the measuring instruments (enclosing non-metallic compo-
nents) was tested with a reduced impact energy of 2 J corresponding to IK07
per EN 61010-1:2010. The IK code is included on the respective product label.
Specifications
Nominal size
Accuracy
Scale ranges
(EN 837)
Max. working pressure
(stat.)
Overload safety
Permissible tempera-
tures
Ingress protection
Media chamber (wetted) Aluminium, EN AC–Al Si9Cu3(Fe), black lacquered
Process connections
(wetted)
Pressure elements
(wetted)
Transmission parts
(wetted)
Sealings (wetted)
Movement
16
Differential pressure indication: Ø 100 mm
Working pressure indication: Ø 22 mm
Differential pressure indication: ≤ 2.5 % of span
(option ≤ 1.6 %)
Working pressure indication: ≤ 4 % of span
Differential pressure: 0 ... 0.25 up to 0 ... 10 bar
Working pressure: 0 ... 25 bar
25 bar
Either side max. 25 bar
Ambient: -10 ... +70 °C, medium: -10 ... +90 °C
Storage: -40 ... +70 °C
IP65 per IEC/EN 60529
(option: stainless steel)
2 x G 1/4 female, lower mount (LM), in-line, centre distance
26 mm
Differential pressure: Compression springs from stainless
steel 1.4310 and separating diaphragm from FPM/FKM
(option: NBR)
Working pressure: Bourdon tube from Cu-alloy
Stainless steel 1.4301, 1.4305, 1.4310, FPM/FKM
(option: NBR)
FPM/FKM (option: NBR)
Copper alloy
WIKA operating instructions DPGS40TA with component testing

Werbung

Kapitel

Inhaltsverzeichnis
loading

Inhaltsverzeichnis