9. Specifications

9. Specifications
Specifications
Nominal size (NS)
Accuracy
1)
Maximum pressure limitation
Permissible temperature range
Temperature effect
Ingress protection per IEC/EN 60529
Process connection
Material
Connection location
Type of measuring element
Dial
Material
Scale angle
Instrument pointer
Case
Window
1) Including non-linearity, hysteresis, zero offset and end value deviation
WIKA operating instructions model 116.18.02x
Ø 23 mm [0.91"]
Ø 24 mm [0.94"]
Ø 25 mm [0.98"]
Ø 26 mm [1.02"]
±5 % of measuring span
±2.5 % at a defined pressure value
Steady: 3/4 x full scale value
Short time: Full scale value
Ambient: -20 ... +60 °C [-4 ... +140 °F]
Medium: -20 ... +60 °C [-4 ... +140 °F]
Storage: -40 ... +70 °C [-40 ... +158 °F]
max. ±0.4 %/10 K of span
When the temperature of the measuring system
deviates from the reference temperature (+20 °C)
IP65
Copper alloy, nickel-plated
Copper alloy, natural finish
Centre back mount
Helical tube, copper alloy
Aluminium, white
Plastic, white
Indication angle 120° ±15°
Copper alloy, black
Copper alloy, nickel-plated
Copper alloy, natural finish
Polycarbonate
Ø 27 mm [1.06"]
Ø 28 mm [1.10"]
Ø 29 mm [1.14"]
17