9. Specifications

Specifications of the gas density monitor
Nominal size
Calibration pressure P
Scale range
Permissible ambient temperature
Operation
Storage
Pressure element
Case
Permissible air humidity ≤ 90 % r. h. (non-condensing)
Ingress protection per
IEC/EN 60529
High-voltage test 100 % 2 kV, 50 Hz, 1s
Specifications of the switch contacts
Number of switch con-
tacts
Switching directions
Switching functions
Circuits
32
Do not dispose of with household waste. Ensure a proper disposal in
accordance with national regulations.
100
To customer specification
E
Vacuum and overpressure range with measuring span of
1.6 ... 16 bar [23 ... 232 psi]
(at an ambient temperature of 20 °C [68 °F] and gaseous phase)
-20 ... +60 °C [-4 ... +140 °F]
-40 ... +60 °C [-40 ... +140 °F]
Stainless steel, welded
Gas-tight: Leakage rate ≤ 1 · 10
Test method: Helium mass spectrometry
Stainless steel, with gas filling
Gas-tight: Leakage rate ≤ 1 · 10
Test method: Helium mass spectrometry
IP65
1 magnetic snap-action contact (option 1)
2 magnetic snap-action contacts (option 2)
3 magnetic snap-action contacts (option 3)
Falling pressure
Rising pressure
Normally closed
Normally open
Galvanically connected
Galvanically isolated
mbar · l / s
-8
mbar · l / s
-5
WIKA operating instructions, model GDM-100-T