2. Safety

2.3.5 Intended use in safety applications

All safety functions relate exclusively to the switching function of the instrument.
The display of the differential pressure is not part of the safety function.
EN
The instrument is suitable for use in single-channel safety-related systems in ac-
cordance with IEC 61508 and IEC 61511 up to SIL 2. In a redundant configuration
(HFT ≥ 1), the instruments can be used in a redundant design up to SIL 3.
The instrument is suitable for use in single-channel safety-related systems in
accordance with ISO 13849 up to PL d. In a redundant configuration (HFT ≥ 1),
the instrument can be used up to PL e, if a sufficient external diagnosis is imple-
mented (DC low for PL d / medium for PL e).
2.3.6 Product label and safety marks
S ... with VdTüV "Flow 100" option
10
WARNING!
The safety-related values of the instrument must be compared, for
the appropriate usage case, with the requirements of the applica-
tion.
The specific parameters should always be considered with respect
to the expected switching frequency.
S ... with SIL option
WIKA operating instructions DPGS40TA with component testing