10.4 Adjust power limiting as required

NOTE!
The drive is preset to stage 3 by the supplier. If required
(e. g. if the power level is too low) you can subsequently
adjust the power limiting setting.
1. Press "P" for approx.
5 seconds.
4. Press "+" or press "–" to
select the stage.
5. Press "P", in order
to store the setting.
After resetting of the power level, it is absolutely necessary to repeat the reference run for power limiting
and to conclude the programming again.
Risk of injury if reference run is not undertaken for purposes of power measurement. Also there is a risk of
injury during the reference run process, as the drive develops a high degree of force.
2. Press "+".
(if necessary press several
times) until "4" is displayed.
Low
Factory setting
6. IMPORTANT
Repeat reference run
for power limiting
(refer to page 64).
If the power level is too low, the door movement
will be impaired, particularly if the mechanical
structure of the door is not well balanced.
3. Press "P", the display
shows "7" (stage 3).
Power level
7. Conclude programming
(refer to page 70 /
method 1).
EN
High
65