This will take you to the submenu for setting the submenu items (see table, select with UP and DOWN, confirm with ENTER, change value or
status with UP and DOWN, confirm with ENTER). The settings for each loop are made separately and are retained even after restarting the device.
STANDALONE MODE LOOP (Loop 1 – Loop 4)
Dimmer
Sets brightness
Step time
Sets step time
Fade time
Sets fade time in percent
Delay
Delay time for slave groups
Step 1
15 colors from Color Preset
4 colors from User Color
Blackout
Step 2
Step 3
15 colors from Color Preset
4 colors from User Color
Blackout
---
Step 4

SLAVE MODE

Standard slave mode: Starting from the main display, press MENU to enter the main menu. Now use UP and DOWN to select the menu
item Slave, confirm with ENTER, select Slave Group 0 and again confirm with ENTER. Connect the slave and the master units (same model,
same software version) using a DMX cable, and enable one of the standalone modes on the master unit (Auto, Static, Color Preset, User
Color, Loop). The slave unit will now follow the master unit.
Advanced slave mode:If you wish to control the slave units in master/slave mode using one of the Auto or Loop standalone modes, the
control signal can be reproduced with a time delay of up to 24 steps. The delay is set in the sub-menu item Delay in the relevant standalo-
ne mode, the delay factor is set in the slave menu of the corresponding spotlight. This is a simple way to create a running light effect with a
large number of spotlights that are all the same model and have the same software version. This is otherwise only possible using a suitable
DMX controller and time-consuming programming.
Assign the spotlights to one of up to 24 groups according to preference, whereby several spotlights can be assigned to one group. The
group number is also the factor by which the delay time set in the master unit is multiplied (see setup example).
Main display
Main display
with group number
and delay time in master unit
0–100
0.1 s to 10.0 s
0% to 100%
0.0 s to 2.0 s
Red – C White
User 1 to User 4
Blackout
Red – C White
User 1 to User 4
Blackout
Skip step