Herunterladen Inhalt Inhalt Diese Seite drucken

Cameo FLAT PRO 7 G2 Bedienungsanleitung Seite 6

Professional outdoor flat par can 7 / 12 / 18 x 10 w ip65
Vorschau ausblenden Andere Handbücher für FLAT PRO 7 G2:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 18
1
POWER IN
TRUE 1-compatible power input socket. Operating voltage 100–240 V AC/50–60 Hz. A suitable mains cable with IP65 plug is included. When
not in use, always close with the appropriate rubber sealing cap.
2
POWER OUT
TRUE 1-compatible mains output socket for supplying power to additional Cameo spotlights (for maximum output current, see label on back
of housing). When not in use, always close with the appropriate rubber sealing cap.
3
DMX IN
Male IP65 3-pin XLR socket for connection to a DMX control device (e.g. DMX console) When not in use, always close with the appropriate
rubber sealing cap.
DMX OUT
4
Female IP65 3-pin XLR socket for sending the DMX control signal. When not in use, always close with the appropriate rubber sealing cap.
5
FUSE
IP65 fuse holder for 5 x 20 mm micro fuses. IMPORTANT: Replace the fuse only with a fuse of the same type and of the same value (see
stamp on back of device). In the event of repeated fuse failure, please contact an authorised service centre.
6
PRESSURE EQUALISATION ELEMENT
The pressure equalisation element serves to prevent condensation inside the housing. In order to ensure its proper function, the element
must be protected from contamination.
OLED DISPLAY
7
The OLED display shows the currently activated mode (main display), the menu items in the selection menu and the numerical value or
operating mode in certain menu items. If there is no input for approx. 30 seconds, the display automatically returns to the main display.
Note regarding the main display in operating modes with external control: As soon as the control signal is interrupted, the characters in the
display begin to flash. When there is a control signal again, the flashing stops. Briefly pressing UP on the control panel when in the main
display rotates the display by 180°.
ILLUMINATED CONTROL PANELS
8
Illumination of the control panels is activated as soon as one of the capacitive control panels is touched; only then is operation via control
panels possible. If no input is made within approx. 30 seconds, the control panel illumination goes off.
MENU – Press MENU to access the selection menu. Press repeatedly to return to the main display. Pressing MENU without confirming a
value or status change with ENTER restores the previously confirmed value or status.
ENTER – Press ENTER to access the menu levels to make value changes and use the ENTER control field to access the submenus. Confirm
value or status changes by pressing ENTER.
UP and DOWN – Select individual menu items in the selection menu (DMX address, operating mode etc.) and in the submenus.
Allow changes to the value in a menu item, such as the DMX address, as required.
9
STAND AND MOUNTING BRACKET
Four rubber feet on the underside of the stand and/or mounting bracket ensure that it can be securely placed on suitable surfaces while at
the same time protecting the surface from scratches. When installing the traverse mounting, use an optional traverse clamp (Omega bracket
and the 16 mm spigot SPIN16® with folding mechanism are available as options).
CARRY HANDLE/SECURING POINT
10
The practical carry handle also serves to secure the spotlight in the event of traverse mounting.
11
GRIP SCREWS
The two grip screws are used for adjusting and fixing the stand and/or mounting bracket.
PLEASE NOTE: To protect the input and output sockets from splash water in accordance with IP65 protection class, they must be correctly
closed using the appropriate IP65 plugs or the rubber sealing caps must be used to close them.