Electrical pre-equipment

Cables required

• Power supply: 3 x 1.5 mm² cable or 3 x 2.5 mm² for outdoor use (type H07RN-F minimum)
• Connection between the motors: 2 x 1 mm² cable; fit an IP 55 junction box to protect the connection between the cable leaving the motor
and the extension which goes to the control unit.
• Linking of cells: 2 x 0.75 mm cable
Provision must be made for the power supply cable
to be fed through in accordance with the electrical
standards in force in the country of use.
Motor cable
Extension to the control
unit
Cable run
• Underground cables must be equipped with a protective sheath with a sufficient diameter to contain all the cables.
• Fit a 230 V electrical input as close as possible to the control unit.
If a cable conduit cannot be made, use a cable grommet which will withstand the weight of vehicles (ref. 2400484).
Cables required
The details of the wiring are indicated in section "Wiring the accessories", page 23
230 V power
EN - EXAVIA installation and operating guide - SOMFY
supply
10