12. Maintenance

12.1

Cleaning and servicing

!
Before cleaning and servicing, switch off
MT 857 L and disconnect mains plug.
!
Do not use any solvent-based cleaning agents. Use
alcohol or similar cleaning agents for plastic parts.
12.2

Service intervals

The following work is essential to ensure proper
operation and high performance of the MT 857 L:
Servicing
Clean moving mechanical parts, treat with spray
oil or kerosene and lubricate with engine oil or a
suitable grease.
Calibrating the electronic vernier caliper
Flange calibration.
MT 857 L calibration.
Perform reference measurement.
i
The calibration is described in the section

"Calibration".

i
As part of service and upkeep (every six months), on
flange replacement or in the event of measurement
inaccuracies, it is advisable to calibrate the
MT 857 L in the following sequence.
12.3

Spare and wearing parts

The manufacturer cannot accept any liability for
damage arising from the use of non-genuine
replacement parts.
Designation
Standard centering flange
Centering cone 42 - 65 mm
Centering cone 54 - 80 mm
Centering cone 60 - 74 mm
Centering cone 72 - 94 mm
Centering cone 75 - 110 mm
Centering cone 89 - 132 mm
Centering cone 90 - 112 mm
Clamp for counter-weights
Weight position sensor
Width gauge
60 g counter weight
Voltage sticker V 230
Voltage sticker V 110
Direction of wheel rotation sticker
Beissbarth GmbH
Designation
"Start/stop balancing" label
Electrical-voltage label
Software version label
Laser safety label
Pedal sign for mechanical version
Tab. 6:
12.4
i
As part of service and upkeep (every six months), on
flange replacement or in the event of measurement
inaccuracies, it is advisable to calibrate the
MT 857 L in the following sequence:
1. Flange calibration.
2. Calibrate the electronic vernier caliper.
3. MT 857 L calibration.
4. Perform reference measurement.
x
12.4.1
1. Call up the "Settings and service" menu.
x
x
x
x
2. Enter the password: <r> <r> <o>.
"
The calibration menu is displayed.
Calibration using wheel and balance weight.
Flange calibration.
Press < I > to return to the previous page.
Order number
Calibration of electronic vernier caliper.
1 695 601 010
1 695 632 500
1 695 652 862
1 695 655 841
1 695 655 840
1 695 605 600
1 695 653 449
1 695 655 839
1 695 606 500
1 695 629 400
1 695 602 700
1 695 654 377
1 695 101 269
1 695 100 854
1 695 653 878
Maintenance | MT 857 L | 87
Spare and wearing parts
Calibration

Call-up of calibration menu

1 695 656 930
en
Order number
1 695 628 500
1 695 100 789
1 695 043 437
1 695 601 027
1 695 600 964
|
2019-08-05

Quicklinks ausblenden: