Herunterladen Inhalt Inhalt Diese Seite drucken

3-Phase Mains Connection 480 V; Rated Data - Lenze i950 Montage- Und Einschaltanleitung

Vorschau ausblenden Andere Handbücher für i950:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

3-phase mains connection 480 V

Rated data

Inverter
Rated power
Rated power
Mains voltage range
Output voltage
Rated mains current
without mains choke
with mains choke
Apparent output power
Rated output current
2 kHz
4 kHz
8 kHz
16 kHz
Power loss
2 kHz
4 kHz
8 kHz
16 kHz
Cyclic mains switching
Max. shielded motor cable
length
without EMC category
Category C1 (2 kHz, 4 kHz, 8
kHz)
Category C2 (2 kHz, 4 kHz, 8
kHz)
Category C3 (2 kHz, 4 kHz, 8
kHz)
Weight
Weight
155F 175F 222F 240F 275F 311F 315F 322F 330F 345F 355F 375F
P
kW
0.55
0.75
rated
P
HP
0.75
1
rated
A
2.1
2.8
A
1.7
2.2
kVA
1.2
1.6
A
1.6
2.1
A
1.6
2.1
A
1.6
2.1
A
1.1
1.4
W
33
39
W
34
41
W
40
49
W
40
49
m
m
m
m
m
kg
m
lb
I95AE
2.2
4
7.5
11
3
5
10
15
3/PE AC 340 V ... 528 V, 45 Hz ... 65 Hz
3 AC 0 - 400/480 V
6.5
10.5
16.6
23.7
4.4
7.5
13.1
18.6
3.8
6.4
11
16
4.8
8.2
14
21
4.8
8.2
14
21
4.8
6.2
14
21
2.2
2.5
7.8
71
111
186
256
75
117
197
272
94
149
252
351
94
149
252
351
3-mal pro Minute
50
35
1.6
3.9
3.5
8.6
Technical data
3-phase mains connection 480 V
15
22
30
45
20
30
40
60
-
47.4
24
35.3
45.7
66.7
22
32
41
60
27
40.4
52
77
27
40.4
52
77
19.8
40.4
52
77
7.2
26.9
34.6
51.3
342
505
653
934
363
536
694
994
471
694
898
1292 1593 2157
471
694
898
1292 1593 2157
100
-
20
10.7
16.7
23.6
37
Rated data
55
75
75
100
-
83
113
75
100
96
124
96
124
96
124
66.8
78.5
1151 1553
1224 1654
200
100
24
53
185