Technical data
Standards and operating conditions
Conformities and approvals
Conformity
CE
EAC
RoHS
Approvals
UL
Protection of persons and device protection
Degree of protection
EN
UL
Insulation resistance
Overvoltage category
Isolation of control circuits
Leakage current
AC
DC
Starting current
Protective measures
Earth fault resistance
Stalling protection,
motor
Short-circuit-proof
Overvoltage protection
Overtemperature of
motor
EMC data
Operation on public supply systems
> 1 kW, line current ≤ 16
A
< 1 kW
Line current > 16 A
Noise emission
Category C1
Category C2
Category C3
Noise immunity
2006/42/EC
2014/30/EU
TP TC 020/2011
TP TR 004/2011
2011/65/EU
UL 61800-5-1
EN 60529
IP20
UL 50
Type 1
UL 61800-5-1
Open type
II
EN 61800-5-1
III
EN 61800-5-1
Safe line voltage isolation
> 3.5 mA
EN 61800-5-1
> 10 mA
≤ 3 x rated mains current
Without additional measures
EN 61000-3-2
With mains choke
With mains choke or mains
EN 61000-3-12
filter
EN 61800-3
EN 61800-3
Requirements met
Machinery Directive, only relevant for (permissible)
safety components, such as encoder or brake
EMC Directive (reference: CE-typical drive system)
Eurasian conformity: Electromagnetic compatibility of
technical means
Eurasian conformity: Safety of low voltage equipment
Restrictions on the use of certain hazardous substances
in electrical and electronic devices
File No. E132659
For USA and Canada (requirements of CSA 22.2 No.
274)
Data applies for operationally ready mounted state and
not in wire range of terminals
Only protection against accidental contact
Only in UL-approved systems
> 2000 m amsl
0 ... 2000 m amsl
double/reinforced insulation
Please observe regulations and safety instructions!
PTC or thermal contact, I²xt monitoring
Compliance with requirements for the machine/system
is the responsibility of the machine/system
manufacturer!
When sizing for rated power.
See rated data
Technical data
EMC data
179