SATAjet 100 B F (RP / HVLP), B P Operating Instructions
Description
Recommended spray
distance, Lombardy,
Italy
Air consumption
Max. material tempera-
ture
Weight (without mate-
rial) of 600 ml plastic
gravity flow cup
Weight (without ma-
terial) of 600 ml RPS
gravity flow cup
Weight (without mate-
rial) of 1000 ml alumi-
num gravity flow cup
8. Operation
Danger!
Risk of injury from bursting compressed-air hose
If unsuitable compressed-air hoses are used, excessive pressure can
damage them and cause them to burst.
→ Use only solvent-resistant, anti-static and technically sound hoses for
compressed air with resistance to continuous pressure of at least 10 bar,
leakage resistance of < 1 MOhm and a min. inside diameter of 9 mm
(# 53090).
Notice!
Damage due to contaminated compressed air
Use of contaminated compressed air can lead to
malfunctions.
→ Use clean compressed air. For example, through SATA filter 100
(# 148247) outside the spray booth or SATA filter 484 (# 92320) inside
the spray booth.
Before using observe/check the following points / to ensure safe operation
RP
−
10.2 cfm at 2,0
bar
21.5 oz.
HVLP
5.1" - 8.3"
12.4 cfm at 2,0
bar
21.2 oz.
16.9 oz.
Polyester
−
8.7 cfm at 2,0
bar
122 °F
21.6 oz.
17.2 oz.
21.9 oz.
US
559