Malfunction
Spray pattern too
small, slanted,
one-sided or split.
Round/flat fan control
not working – control
can be turned.
Round/flat fan control
cannot be turned.
Paint spray gun does
not shut off air.
Material bubbles up in
gravity flow cup.
568
Cause
Bore holes in air noz-
zle clogged with paint.
Paint nozzle tip (paint
nozzle in) damaged.
Air distribution ring
positioned incorrectly
(pin not in bore hole)
or damaged.
Round/flat fan control
turned too sharply
counterclockwise;
spindle in gun thread-
ing loose.
Air piston seat dirty.
Air piston is worn.
Atomized air entering
gravity flow cup via
paint passage. Paint
nozzle not tightened
enough. Air nozzle not
screwed on complete-
ly, air circuit clogged,
faulty seating or dam-
aged nozzle insert.
Corrective action
Clean air nozzle. Read
and follow cleaning
instructions (see 10).
Check paint nozzle tip
for damage and replace
nozzle set if necessary
(see 9.1).
Replace air distribution
ring (see 9.2).
Remove round/flat fan
control with universal
wrench and make oper-
ational or replace com-
pletely (see 9.6).
Clean air piston seat.
Read and follow
cleaning instructions
(see 10).
Replace air piston
and air piston packing
(see 9.4).
Secure, clean or re-
place parts.