Herunterladen Inhalt Inhalt Diese Seite drucken

Maintenance And Repairs - SATA SATAjet 100 B F RP Betriebsanleitung

Vorschau ausblenden Andere Handbücher für SATAjet 100 B F RP:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Operating Instructions SATAjet 100 B F (RP / HVLP), B P
EN
■ Pull trigger guard right back [6-2] and hold spray gun at 90° to the
surface being sprayed [6-1].
■ Ensure there is sufficient spraying air feed and material supply.
■ Pull trigger guard [1-11] back and start spraying process. Adjust mate-
rial flow and spray fan pattern if necessary.
End the spraying process
■ Bring the trigger guard [1-11] to the starting position.
■ At the end of the spraying process, interrupt the spraying air and empty
the gravity flow cup [1-16]. Comply with the instructions for care and
storage (see chapter 10).

9. Maintenance and repairs

Warning!
Risk of injuries from components coming loose or leaking
material.
If maintenance work is performed while still connected to the com-
pressed air circuit, components can unexpectedly work loose and mate-
rial can leak.
→ Always disconnect the spray gun from the compressed air circuit
before performing any maintenance work.
Warning!
Risk of injury from sharp edges
There is a risk of injury from sharp edges when fitting the nozzle set.
→ Wear protective gloves.
→ Always use the SATA extraction tool pointing away from your body.
The following chapter describes the procedures involved for maintaining
and repairing the
spray gun. Maintenance and repair work may only be
carried out by trained skilled workers.
■ Always interrupt the compressed air supply to the compressed air con-
nection [1-8] before performing any maintenance and repair work.
Spare parts are available for carrying out repairs (see chapter 15).
140

Werbung

Inhaltsverzeichnis

Fehlerbehebung

loading

Diese Anleitung auch für:

Satajet 100 b f hvlpSatajet 100 b p

Inhaltsverzeichnis