Herunterladen Inhalt Inhalt Diese Seite drucken
Vorschau ausblenden Andere Handbücher für SATAjet 100 B F RP:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Operating Instructions SATAjet 100 B F (RP / HVLP), B P
Description
Recommended spray-
ing distance
Recommended spray
distance Lombardy / It-
aly
Air consumption
Max. temperature of
the spray medium
Weight (without ma-
terial) plastic flow cup
600 ml
Weight (without materi-
al) RPS cup 600 ml
Weight (without materi-
al) aluminium flow cup
1000 ml

8. Operation

Warning!
Risk of injury from bursting compressed air hose
If an unsuitable compressed air hose is use, it can be damaged by too
much pressure and explode.
→ Only use solvent-resistant, antistatic and technically flawless hose
for compressed air with permanent pressure resistance of min. 10 bar,
bleeder resistance of < 1 MOhm and min. inner diameter of 9 mm
(# 53090).
Attention!
Damage from dirty compressed air
Using soiled compressed air can cause malfunctions
.
→ Use clean compressed air. For example with SATA filter 100
(# 148247) outside the spray booth or SATA filter 484 (# 92320) inside
the spray booth.
RP
17 cm - 21 cm 10 cm - 15 cm 17 cm - 21 cm
290 Nl/min at
2,0 bar
610 g
HVLP
13 cm - 21 cm
350 Nl/min at
2,0 bar
601 g
478 g
Polyester
245 Nl/min at
2,0 bar
50 °C
612 g
489 g
621 g
EN
137

Werbung

Inhaltsverzeichnis

Fehlerbehebung

loading

Diese Anleitung auch für:

Satajet 100 b f hvlpSatajet 100 b p

Inhaltsverzeichnis