SATA spray master RPOperating Instructions
US
Malfunction
Corrosion on air noz-
zle threading, material
passage (material
connection) or paint
spray gun body.
Spray medium es-
capes behind paint
needle packing.
Paint spray gun drip-
ping at fluid tip pin.
12. Disposal
Dispose of completely emptied paint spray gun as recyclable material.
To prevent harming the environment, properly dispose of any remaining
spray medium and stripping agent separately from the paint spray gun.
Comply with local regulations!
13. After Sale Service
Please ask your SATA dealer for accessories, spare parts and technical
support.
14. Accessories
Part No.
6981
64030
9902
48173
534
Cause
Cleaning fluid (aque-
ous) remains too long
on gun.
Unsuitable cleaning
agent.
Faulty or missing paint
needle packing.
Paint needle dam-
aged.
Paint needle dirty.
Foreign body between
paint needle tip and
paint nozzle.
Nozzle set damaged.
Description
Quick coupling nipple G 1/4" (female thread)
SATA cleaning set
Air hose
High performance grease
Corrective action
Have gun body re-
placed. Read and follow
cleaning instructions
(see 10).
Replace the paint nee-
dle packing.
Replace nozzle set
(see 9.2).
Clean paint needle.
Read and follow
cleaning instructions
(see 10).
Clean paint nozzle and
paint needle. Read and
follow cleaning instruc-
tions (see 10).
Replace nozzle set
(see 9.2).
Quan-
tity
5 ea.
1 set
1 ea.
1 ea.