Herunterladen Inhalt Inhalt Diese Seite drucken

Disposal; After Sales Service; Accessories - SATA spray master RP Betriebsanleitung

Vorschau ausblenden Andere Handbücher für spray master RP:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Operating Instructions SATA spray master RP
EN
Malfunction
Material leaks from
behind the paint nee-
dle seal.
Spray gun drips at
fluid tip ("fluid tip aper-
ture").

12. Disposal

Dispose of the completely emptied spray gun as a recyclable material.
To avoid damage to the environment, dispose of the spray material and
release agent separately from the spray gun in an appropriate manner.
Comply with local regulations!

13. After Sales Service

For accessories, spare parts and technical support, contact your SATA
dealer.

14. Accessories

Art. No.
6981
64030
9902
48173
10009
138
Cause
Paint needle seal de-
fective or missing.
Paint needle dam-
aged.
Paint needle clogged.
Contamination be-
tween paint needle tip
and fluid tip.
Damaged nozzle set.
Description
Quick coupling nipple G1/4 IG
SATA cleaning set
Air hose
High performance grease
High performance grease
Corrective action
Replace paint needle
seal.
Replace nozzle set (see
chapter 9.2).
Clean paint needle.
Heed cleaning instruc-
tions (see chapter 10).
Clean fluid tip and paint
needle. Heed cleaning
instructions (see chap-
ter 10).
Replace nozzle set (see
chapter 9.2).
Num-
ber
5 ea.
1 set
1 ea.
1 ea.
6 units