9. Maintenance and repairs
Warning!
Risk of injuries from components coming loose or leaking
material.
If maintenance work is performed while still connected to the com-
pressed air circuit, components can unexpectedly work loose and mate-
rial can leak.
→ Always disconnect the spray gun from the compressed air circuit
before performing any maintenance work.
Warning!
Risk of injury from sharp edges
There is a risk of injury from sharp edges when fitting the nozzle set.
→ Wear protective gloves.
The following chapter describes the procedures involved for maintaining
and repairing the
spray gun. Maintenance and repair work may only be
carried out by trained skilled workers.
■ Always interrupt the compressed air supply to the compressed air con-
nection [1-9] before performing any maintenance and repair work.
Spare parts are available for carrying out repairs (see chapter 15).
9.1. Replace trigger guard
Remove trigger guard
■ Loosen counter nut of adjusting screw [1-4].
■ Screw adjusting screw with counter nut out of gun body.
■ Remove spring and paint needle.
■ Carefully remove circlips.
■ Pull both bolts out.
■ Remove trigger guard.
Mount trigger guard
■ Insert trigger guard.
■ Insert guard bolt.
■ Insert circlips.
■ Insert paint needle and spring.
■ Screw adjusting screw [1-4] with counter nut into gun body.