SATA spray master RPOperating Instructions
Notice!
Damage due to contaminated compressed air
Use of contaminated compressed air can lead to
malfunctions.
→ Use clean compressed air. For example, through SATA filter 100
(# 148247) outside the spray booth or SATA filter 484 (# 92320) inside
the spray booth.
Before using observe/check the following points / to ensure safe operation
of the paint spray gun:
■ All screws [# 1503], [# 61416] and [# 133967] are tight. Tighten
screws, if necessary.
■ Air nozzle are attached securely
■ Paint nozzle is tightened with a tightening torque of 14 Nm.
■ Technically clean compressed air used.
8.1. Initial Operation
■ Purge compressed air hose thoroughly prior to assembly.
■ Flush paint passage with suitable cleaning agent.
■ Thread connection nipple onto air connection.
■ Connect compressed air hose to air valve [1-9].
■ Adjust internal cup pressure according to the material to be
used.
■ Adjust air nozzle.
■ Set the air nozzle horns vertically when spraying horizontally.
■ Set the air nozzle horns horizontally when spraying vertically.
8.2. Normal Operation
Connecting the paint spray gun
■ Connect compressed air hose to air connection [1-9].
Adding material
Information!
When painting use only the quantity of material required for the work
step.
Maintain the necessary spray distance when painting. Store or dispose
of the material properly after painting.
■ Remove screw-on lid [1-15] of gravity flow cup [1-14].
■ Remove anti-drip device [# 70664].
US