Konfiguration mit dem TwinCAT System Manager
Index 1A03 STM TxPDO-Map Status
Index
Name
1A03:0
STM TxPDO-Map
Status
1A03:01
SubIndex 001
1A03:02
SubIndex 002
1A03:03
SubIndex 003
1A03:04
SubIndex 004
1A03:05
SubIndex 005
1A03:06
SubIndex 006
1A03:07
SubIndex 007
1A03:08
SubIndex 008
1A03:09
SubIndex 009
1A03:0A
SubIndex 010
1A03:0B
SubIndex 011
1A03:0C
SubIndex 012
1A03:0D
SubIndex 013
1A03:0E
SubIndex 014
Index 1A04 STM TxPDO-Map Synchron info data
Index
Name
1A04:0
STM TxPDO-Map
Synchron info da-
ta
1A04:01
SubIndex 001
1A04:02
SubIndex 002
Index 1A05 STM TxPDO-Map Motor load
Index
Name
1A05:0
STM TxPDO-Map
Motor load
1A05:01
SubIndex 001
208
Bedeutung
PDO Mapping TxPDO 4
1. PDO Mapping entry (object 0x6010 (STM Inputs
Ch.1), entry 0x01 (Ready to enable))
2. PDO Mapping entry (object 0x6010 (STM Inputs
Ch.1), entry 0x02 (Ready))
3. PDO Mapping entry (object 0x6010 (STM Inputs
Ch.1), entry 0x03 (Warning))
4. PDO Mapping entry (object 0x6010 (STM Inputs
Ch.1), entry 0x04 (Error))
5. PDO Mapping entry (object 0x6010 (STM Inputs
Ch.1), entry 0x05 (Moving positive))
6. PDO Mapping entry (object 0x6010 (STM Inputs
Ch.1), entry 0x06 (Moving negative))
7. PDO Mapping entry (object 0x6010 (STM Inputs
Ch.1), entry 0x07 (Torque reduced))
8. PDO Mapping entry (object 0x6010 (STM Inputs
Ch.1), entry 0x08 (Motor stall))
9. PDO Mapping entry (3 bits align)
10. PDO Mapping entry (object 0x6010 (STM Inputs
Ch.1), entry 0x0C (Digital input 1))
11. PDO Mapping entry (object 0x6010 (STM Inputs
Ch.1), entry 0x0C (Digital input 2))
12. PDO Mapping entry (object 0x6010 (STM Inputs
Ch.1), entry 0x0E (Sync error))
13. PDO Mapping entry (1 bits align)
14. PDO Mapping entry (object 0x6010 (STM Inputs
Ch.1), entry 0x10 (TxPDO Toggle))
Bedeutung
PDO Mapping TxPDO 5
1. PDO Mapping entry (object 0x6010 (STM Inputs
Ch.1), entry 0x11 (Info data 1))
2. PDO Mapping entry (object 0x6010 (STM Inputs
Ch.1), entry 0x12 (Info data 2))
Bedeutung
PDO Mapping TxPDO 6
1. PDO Mapping entry (object 0x6010 (STM Inputs
Ch.1), entry 0x13 (Motor load))
Version: 1.8
Datentyp
Flags
Default
UINT8
RO
0x0E (14
UINT32
RO
0x6010:01, 1
UINT32
RO
0x6010:02, 1
UINT32
RO
0x6010:03, 1
UINT32
RO
0x6010:04, 1
UINT32
RO
0x6010:05, 1
UINT32
RO
0x6010:06, 1
UINT32
RO
0x6010:07, 1
UINT32
RO
0x6010:08, 1
UINT32
RO
0x0000:00, 3
UINT32
RO
0x6010:0C, 1
UINT32
RO
0x6010:0D, 1
UINT32
RO
0x6010:0E, 1
UINT32
RO
0x0000:00, 1
UINT32
RO
0x6010:10, 1
Datentyp
Flags
Default
UINT8
RO
0x02 (2
UINT32
RO
0x6010:11, 16
UINT32
RO
0x6010:12, 16
Datentyp
Flags
Default
UINT8
RO
0x01 (1
UINT32
RO
0x6010:13, 16
)
dez
)